Comparison of changes in the expiratory capnogram waveform and regional ventilation distribution measured by synchrotron imaging during acute bronchoconstriction in brown Norway rat

M. Guilbart, L. Porra, L. Degrugilliers, B. Babik, F. Robidel, F. Rogerieux, F. Marchal, B. Chenuel, S. Bayat (Helsinki, Finland; Amiens, Vandoeuvre les Nancy, France; Szeged, Hungary)

Source: Annual Congress 2012 - Modern clinical physiology: imaging structure and evaluating function
Session: Modern clinical physiology: imaging structure and evaluating function
Session type: Oral Presentation
Number: 1653
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
M. Guilbart, L. Porra, L. Degrugilliers, B. Babik, F. Robidel, F. Rogerieux, F. Marchal, B. Chenuel, S. Bayat (Helsinki, Finland; Amiens, Vandoeuvre les Nancy, France; Szeged, Hungary). Comparison of changes in the expiratory capnogram waveform and regional ventilation distribution measured by synchrotron imaging during acute bronchoconstriction in brown Norway rat. Eur Respir J 2012; 40: Suppl. 56, 1653

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
The acute effects of postural change and non-invasive ventilation breathing on the regional distribution of lung ventilation: An electrical impedance tomography study
Source: Annual Congress 2012 - Current trends in home mechanical ventilation
Year: 2012

Contribution of lung ventilation and perfusion distributions to the phase III slope of exhaled CO2 during acute bronchoconstriction studied by synchrotron imaging in rabbit
Source: Annual Congress 2013 –Clinical physiology and functional imaging in health and disease
Year: 2013

Combined effects of body positioning and noninvasive ventilation on the regional distribution of pulmonary ventilation evaluated by electrical impedance tomography in the young and the elderly.
Source: International Congress 2019 – Treatment of acute respiratory failure with noninvasive ventilation
Year: 2019

The effect of high-frequency oscillatory vibration on peak expiratory flow generated by a MI-E cough assist device in a mechanical lung model
Source: International Congress 2018 – Chronic respiratory disease: respiratory muscle function, breathing exercises and airway clearance techniques
Year: 2018

Non-invasive measurements of dynamic hyperinflation and breathing pattern during exercise
Source: Eur Respir J 2004; 24: Suppl. 48, 217s
Year: 2004

Electrical impedance tomography monitoring for predicting lung collapse after positive end expiratory pressure decrement in recovering acute respiratory distress syndrome
Source: Virtual Congress 2021 – Severe acute respiratory failure
Year: 2021



Assessing global and regional pulmonary function with electrical impedance tomography in pediatric patients: the EIT-derived flow-volume loops
Source: Virtual Congress 2020 – Respiratory physiology and sleep: what is new?
Year: 2020


Recording flow in the first second of a maximal forced expiratory manoeuvre: influence of frequency content
Source: Eur Respir J 2002; 19: 530-533
Year: 2002



Bronchodilator acutely reduces expiratory flow limitation during exercise in COPD demonstrated by dynamic hyperinflation, flow-volume curve analysis and impulse oscillometry
Source: Virtual Congress 2020 – From respiratory physiology to diagnosis and treatment
Year: 2020


Gravity dependent ventilation distribution in rats measured with electrical impedance tomography
Source: Annual Congress 2010 - Airways and lung mechanics in subjects of all ages
Year: 2010


Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP
Source: Eur Respir J 2006; 27: 983-991
Year: 2006



Heterogeneity of regional lung ventilation in COPD patients determined by electrical impedance tomography
Source: Annual Congress 2010 - COPD: treatment and monitoring
Year: 2010

Measurement of tidal breathing flows in infants using impedance pneumography
Source: Eur Respir J , 49 (2) 1600926; DOI: 10.1183/13993003.00926-2016
Year: 2017



Determination of regional opening and closing pressures in ALI patients by electrical impedance tomography
Source: Annual Congress 2010 - Acute lung injury and ventilator-induced lung injury
Year: 2010


Regional lung mechanics during a novel recruitment manoeuvre assessed with electrical impedance tomography (EIT)
Source: Eur Respir J 2005; 26: Suppl. 49, 391s
Year: 2005

Timing of chest wall vibrations within the breath cycle: effects on peak flow and pressure in a ventilated lung model
Source: Annual Congress 2009 - Chest physiotherapy in critically ill patients
Year: 2009


Regional expiratory flow limitation during spontaneous breathing: comparison of overall and regional lung function
Source: Eur Respir J 2001; 18: Suppl. 33, 94s
Year: 2001

Dynamic hyperinflation in COPD: influence of measuring technique, breathing frequency and tidal volume
Source: Eur Respir J 2007; 30: Suppl. 51, 340s
Year: 2007

Non-invasive monitoring of lung volume recruitment/derecruitment by forced oscillations technique (FOT)
Source: Eur Respir J 2007; 30: Suppl. 51, 1s
Year: 2007

Changes in regional distribution of gas and blood volumes within a single respiratory cycle: Effect of tidal volume, PEEP and respiratory pattern
Source: International Congress 2014 – Functional imaging
Year: 2014