Longitudinal changes in detrended fluctuation analysis "alpha" of PEF in COPD

G. Donaldson, T. Seemungal, J. Hurst, U. Frey, J. Wisia (London, United Kingdom; St. Augustine, Trinidad And Tobago; Basel, Switzerland)

Source: Annual Congress 2012 - COPD comorbidities II
Session: COPD comorbidities II
Session type: Thematic Poster Session
Number: 550
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
G. Donaldson, T. Seemungal, J. Hurst, U. Frey, J. Wisia (London, United Kingdom; St. Augustine, Trinidad And Tobago; Basel, Switzerland). Longitudinal changes in detrended fluctuation analysis "alpha" of PEF in COPD. Eur Respir J 2012; 40: Suppl. 56, 550

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Detrended fluctuation analysis of peak expiratory flow and exacerbation frequency in COPD
Source: Eur Respir J 2012; 40: 1123-1129
Year: 2012



Spectral analysis and detrended fluctuation analysis on heart rate variability recognises sleep stages and sleep apnea
Source: Eur Respir J 2003; 22: Suppl. 45, 272s
Year: 2003

Determinants of COPD exacerbations by monitoring the peak expiratory flow rate and seasonal variation in Thailand: A retrospective study
Source: Virtual Congress 2020 – Physiotherapy in acute respiratory care
Year: 2020


The annual decline in FEV1 is steeper if it is estimated from baseline data using cross-sectional analysis than obtained by longitudinal analysis
Source: Annual Congress 2008 - Air pollution effects on lung and heart
Year: 2008


The relationship between long-term correlations (self-similarity) in PEF and FEV1 in COPD
Source: Annual Congress 2012 - New issues in pulmonary function
Year: 2012

Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects
Source: ERJ Open Res 2016: 00094-2015
Year: 2016



Amplitude analysis of pressure oscillations after interruption of tidal breathing for bronchodilator response (BDR) assessment
Source: Eur Respir J 2003; 22: Suppl. 45, 130s
Year: 2003

Diurnal variation and serial changes of peak expiratory flow in adult patients with cough variant asthma
Source: Eur Respir J 2004; 24: Suppl. 48, 588s
Year: 2004

Determinants of the relationship between changes in FEV1 and SGRQ: analysis of the TORCH data
Source: Annual Congress 2008 - COPD
Year: 2008


Natural decline in FEV1 and FVC: Self versus reference equations
Source: Annual Congress 2013 –Reference, reliability and risk: advances in lung function
Year: 2013


Spirometric parmameters during single examination, besides peak expiratory flow (PEF) variability, do not correlate with quality of life (QL) in children with stable asthma
Source: Eur Respir J 2006; 28: Suppl. 50, 256s
Year: 2006

Relation between occurrence of asthma symptoms and peak expiratory flow: an analysis of diary cards
Source: Annual Congress 2003 - Novel approaches to asthma management and monitoring
Year: 2003


Drivers of year-to-year variation in exacerbation frequency of COPD: analysis of the AERIS cohort
Source: ERJ Open Res, 5 (1) 00248-2018; 10.1183/23120541.00248-2018
Year: 2019



Variability of forced oscillation technique and correlation with spirometry in adults
Source: Eur Respir J 2004; 24: Suppl. 48, 575s
Year: 2004

Prospective analysis of lung function in COPD patients – home monitoring of FEV1 and PEF (PIKO®1)
Source: Eur Respir J 2006; 28: Suppl. 50, 108s
Year: 2006

The effect of shift work on serial peak expiratory flow measurements used for diagnosing occupational asthma
Source: Annual Congress 2010 - Occupational asthma
Year: 2010

Duration and frequency of spirometry needed to accurately reflect longitudinal change of FEV1 in COPD
Source: Virtual Congress 2021 – Lung function testing in the management of obstructive diseases
Year: 2021


Analysis of wave reflection and impedance in the patients with COPD using impulse oscillometry
Source: Eur Respir J 2006; 28: Suppl. 50, 421s
Year: 2006

Peak expiratory flow value and relationships between functional parameters in COPD
Source: Eur Respir J 2006; 28: Suppl. 50, 808s
Year: 2006

Dealing with missing longitudinal FEV1 observations when used as time-dependent covariate data in survival analysis for COPD patients within a regional UK population-level database
Source: International Congress 2015 – Epidemiology of respiratory disease
Year: 2015