Breath-by-breath delivered dose comparison from three anti-static valved holding chambers with facemasks under simulated pediatric breathing conditions

W. Hsu, D. von Hollen, Z. Xu, T. Bai, K. Nikander, R. Dalby (Baltimore, Parsippany, United States Of America)

Source: Annual Congress 2011 - Treating childhood asthma
Session: Treating childhood asthma
Session type: Poster Discussion
Number: 4831
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
W. Hsu, D. von Hollen, Z. Xu, T. Bai, K. Nikander, R. Dalby (Baltimore, Parsippany, United States Of America). Breath-by-breath delivered dose comparison from three anti-static valved holding chambers with facemasks under simulated pediatric breathing conditions. Eur Respir J 2011; 38: Suppl. 55, 4831

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
In vitro testing of an improved collapsible valved holding chamber (CHC) with a pressurized metered-dose inhaler delivered bronchodilator, simulating an adult mechanically ventilated patient
Source: Annual Congress 2010 - Treatment options for asthma
Year: 2010


In vitro delivery of an HFA-based corticosteroid by pediatric and adult valved holding chambers (VHC): effect of inhalation flow rate
Source: Eur Respir J 2002; 20: Suppl. 38, 500s
Year: 2002

Antistatic treatment and the amount of salbutamol actuated have variable effect on drug delivery of six different valved holding chambers (VHC)
Source: International Congress 2019 – Severe acute asthma and troublesome wheezing
Year: 2019

In vitro comparison of the effect of inhalation delay on the variability of the delivered dose from valved holding chambers
Source: Annual Congress 2012 - Assessing and treating childhood asthma and allergy
Year: 2012


A visual indicator for inhalation from a valved holding chamber (VHC) is an aid in delivery of inhaled medication to infants and small children via facemask
Source: Annual Congress 2009 - New aspects of inhalation therapy
Year: 2009


Delivery of an HFA-formulated bronchodilator to the mechanically ventilated adult patient via holding chamber: laboratory simulation
Source: Eur Respir J 2003; 22: Suppl. 45, 473s
Year: 2003

Not all antistatic valved holding chambers have equivalent performance: An example why each valved holding chamber (VHC)-inhaler combination should be considered unique
Source: Annual Congress 2012 - The best of pharmacology treatments of airway diseases: new devices and drugs
Year: 2012


Impact of inspiratory delay and valved holding chamber (VHC) material on drug delivery
Source: Eur Respir J 2001; 18: Suppl. 33, 494s
Year: 2001

Assessment of facemask seal leakage from six VHC systems on two pediatric simulated anatomical models under simulated breathing conditions
Source: Annual Congress 2012 - Assessing and treating childhood asthma and allergy
Year: 2012


Medication delivery via infant and child valved holding chambers (VHCs) with facemask is aided with inhalation flow indicator
Source: Annual Congress 2008 - Diagnosing, monitoring and treating respiratory diseases in primary care
Year: 2008


Valved holding chamber drug delivery is dependent on breathing pattern and device design
Source: ERJ Open Res, 5 (1) 00158-2018; 10.1183/23120541.00158-2018
Year: 2019



In-vitro performance of two valved holding chambers (VHCs)/Spacers for paediatric use tested with facemasks attached is unaffected by routine use and cleaning
Source: Annual Congress 2008 - Wheezing in preschool children
Year: 2008

Impact of inhalation delay on medication delivery from a salbutamol HFA pressurized metered dose inhaler used with and without a new prototype portable valved holding chamber
Source: International Congress 2019 – COPD treatment: clinical trials, cohorts and inhaler device studies
Year: 2019

In vitro performance of a small non-electrostatic valved holding chamber made from metal with three different brands of pressurized metered dose inhalers
Source: Eur Respir J 2006; 28: Suppl. 50, 712s
Year: 2006

Comparison of two valved holding chambers for the delivery of an HFA-based solution corticosteroid formulation
Source: Eur Respir J 2002; 20: Suppl. 38, 500s
Year: 2002

Effect of changes in peak inspiratory flow on the dose of salbutamol delivered by nebulizers under simulated conditions
Source: International Congress 2018 – What’s new in lung function and exercise assessment in COPD?
Year: 2018




Performance of a valved holding chamber with tracheostomy adapter: comparison with conventional valved holding chamber
Source: Eur Respir J 2001; 18: Suppl. 33, 134s
Year: 2001

In vitro performance of an improved collapsible holding chamber (CHC) for the delivery of bronchodilators to patients receiving mechanical ventilation
Source: Annual Congress 2011 - Mechanical ventilation and lung injury: new advances
Year: 2011

Evaluation of CO2 rebreathing associated to use of tubular spacers located between mask and expiratory valve in volumetric ventilators. A pilot study in healthy volunteers
Source: Eur Respir J 2006; 28: Suppl. 50, 189s
Year: 2006

In vitro equivalence exists for infant non-conducting (NC) and anti-static (AS) valved holding chambers (VHC) from the same family of add on devices used with pressurized metered dose inhalers (pMDIs) provided pre-conditioning of the non-conducting VHCs is undertaken
Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Year: 2010