Designing a holding chamber mask using anthropometric data and CAD-simulation

A. Söderholm Labre, S. Merk, F. Kummer, K. Behrenbruch (Starnberg, Westensee, Germany)

Source: Annual Congress 2011 - Treating childhood asthma
Session: Treating childhood asthma
Session type: Poster Discussion
Number: 4830
Disease area: Airway diseases, Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. Söderholm Labre, S. Merk, F. Kummer, K. Behrenbruch (Starnberg, Westensee, Germany). Designing a holding chamber mask using anthropometric data and CAD-simulation. Eur Respir J 2011; 38: Suppl. 55, 4830

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Valved holding chamber drug delivery is dependent on breathing pattern and device design
Source: ERJ Open Res, 5 (1) 00158-2018; 10.1183/23120541.00158-2018
Year: 2019



Breath-by-breath delivered dose comparison from three anti-static valved holding chambers with facemasks under simulated pediatric breathing conditions
Source: Annual Congress 2011 - Treating childhood asthma
Year: 2011

Patient centered development of a new valved holding chamber (VHC) designed specifically for on-the-go use
Source: Virtual Congress 2020 – Asthma inhalers: devices and adherence studies
Year: 2020


Clinically appropriate testing of different valved holding chamber (VHC)-facemask combinations investigating simulated delivered mass to carina
Source: International Congress 2015 – Respiratory disease management in primary care
Year: 2015

Assessment of facemask seal leakage from six VHC systems on two pediatric simulated anatomical models under simulated breathing conditions
Source: Annual Congress 2012 - Assessing and treating childhood asthma and allergy
Year: 2012


In-vitro performance of two valved holding chambers (VHCs)/Spacers for paediatric use tested with facemasks attached is unaffected by routine use and cleaning
Source: Annual Congress 2008 - Wheezing in preschool children
Year: 2008

Active cushion technology: objective assessment of mask sealing performance
Source: Eur Respir J 2003; 22: Suppl. 45, 93s
Year: 2003

Medication delivery via infant and child valved holding chambers (VHCs) with facemask is aided with inhalation flow indicator
Source: Annual Congress 2008 - Diagnosing, monitoring and treating respiratory diseases in primary care
Year: 2008


Calibration of a (semi)-automatic measurement and control platform for centralized, simultaneous electronic nose (eNose) analyses in multi-centre trials
Source: Annual Congress 2012 - Exhaled biomarkers to assess airway inflammation
Year: 2012



Effect of different mask design for measuring respiratory input impedance in pre-school children by forced oscillation technique (FOT)
Source: International Congress 2017 – Best abstracts in lung function
Year: 2017



Drug delivery from inhalation devices is dependent on face mask seal and the child's breathing pattern
Source: Eur Respir J 2001; 18: Suppl. 33, 493s
Year: 2001

Performance of a valved holding chamber with tracheostomy adapter: comparison with conventional valved holding chamber
Source: Eur Respir J 2001; 18: Suppl. 33, 134s
Year: 2001

Not all antistatic valved holding chambers have equivalent performance: An example why each valved holding chamber (VHC)-inhaler combination should be considered unique
Source: Annual Congress 2012 - The best of pharmacology treatments of airway diseases: new devices and drugs
Year: 2012


Feasibility of three-dimensional facial imaging and printing for producing customised nasal masks for continuous positive airway pressure
Source: ERJ Open Res, 7 (1) 00632-2020; 10.1183/23120541.00632-2020
Year: 2021



Comparative assessment of several automatic CPAP devices' responses: a bench test study
Source: ERJ Open Res 2015
Year: 2015



Evaluation of a ventilatory monitoring system coupled to a portable ventilator: a bench study
Source: Eur Respir J 2007; 30: Suppl. 51, 571s
Year: 2007

Impact of inspiratory delay and valved holding chamber (VHC) material on drug delivery
Source: Eur Respir J 2001; 18: Suppl. 33, 494s
Year: 2001

Evaluation of a simplified sleep recording and analyzing device at the bedside
Source: Annual Congress 2008 - Diagnostic aspects of sleep apnoea
Year: 2008


Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing
Source: Eur Respir J, 55 (6) 2000846; 10.1183/13993003.00846-2020
Year: 2020



Validation of a technique used to accurately record and simulate breathing from patients using spacer devices
Source: Annual Congress 2008 - Advances in the treatment and pathogenesis of pulmonary diseases
Year: 2008