Comparison of two devices and two breathing patterns for exhaled breath condensate sampling

A. R. Koczulla, E. Hüttmann, T. Greulich, A. Hattesohl, S. Noeske, S. Schmid, J. Gerrit, R. Jörres, B. Müller, C. Vogelmeier (Marburg, Munich, Germany)

Source: Annual Congress 2011 - Bronchial hyperresponsiveness and exhaled and sputum biomarkers
Session: Bronchial hyperresponsiveness and exhaled and sputum biomarkers
Session type: Thematic Poster Session
Number: 4039
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. R. Koczulla, E. Hüttmann, T. Greulich, A. Hattesohl, S. Noeske, S. Schmid, J. Gerrit, R. Jörres, B. Müller, C. Vogelmeier (Marburg, Munich, Germany). Comparison of two devices and two breathing patterns for exhaled breath condensate sampling. Eur Respir J 2011; 38: Suppl. 55, 4039

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Influence of breathing pattern on exhaled breath condensate collection
Source: Eur Respir J 2002; 20: Suppl. 38, 174s
Year: 2002

Effect of varying respiratory pattern on exhaled breath condensate collection
Source: Eur Respir J 2003; 22: Suppl. 45, 37s
Year: 2003

Changes in ventilation and respiratory impedance after sampling of exhaled breath condensate (EBC) in pigs
Source: Eur Respir J 2002; 20: Suppl. 38, 175s
Year: 2002

The collection of exhaled breath condensate depends on various variables of ventilation
Source: Eur Respir J 2005; 26: Suppl. 49, 261s
Year: 2005

Reproducibility of exhaled breath condensate markers
Source: Eur Respir J 2008; 32:
Year: 2008


Separate lung exhaled breath condensate collection confirms intrapulmonary origin of exhaled breath condensate acidification
Source: Eur Respir J 2007; 30: Suppl. 51, 364s
Year: 2007

Possible use of exhaled breath condensate (EBC) for continuous monitoring of lung inflammation in artificial ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

The influence of active and passive air humidification on exhaled breath condensate volume
Source: ERJ Open Res, 6 (4) 00009-2020; 10.1183/23120541.00009-2020
Year: 2020



Fractionated sampling of exhaled breath condensate
Source: Annual Congress 2007 - Noninvasive evaluation of airway diseases
Year: 2007


Determinants of variability in exhaled breath condensate (EBC) in children
Source: Annual Congress 2008 - Inflammatory biomarkers
Year: 2008

Variability of the exhaled breath condensate pH with different methods of analysis
Source: Eur Respir J 2005; 26: Suppl. 49, 260s
Year: 2005

Feasibility of exhaled breath condensate collection in toddlers
Source: Annual Congress 2007 - Airway regulation, provocation and monitoring II
Year: 2007


Reproducibility of exhaled breath condensate pH measurements with a hand-held device in wheezing children
Source: Eur Respir J 2006; 28: Suppl. 50, 789s
Year: 2006

pH measurement in exhaled breath condensate: a comparison between two collection devices
Source: Eur Respir J 2006; 28: Suppl. 50, 790s
Year: 2006

Continuous exhaled breath condensate pH monitoring
Source: Eur Respir J 2004; 24: Suppl. 48, 27s
Year: 2004

Parameters of oxidation in exhaled breath condensate
Source: Eur Respir J 2004; 24: Suppl. 48, 470s
Year: 2004

Metabolomic/proteomic analysis of biomarkers in exhaled breath condensates
Source: Annual Congress 2008 - PG8 - Cellular and molecular technologies of today - treatments of tomorrow
Year: 2008



Collecting exhaled breath condensate from the exhaust port of the ventilator
Source: Eur Respir J 2005; 26: Suppl. 49, 88s
Year: 2005

Rapid measurement of lactate in exhaled breath condensate
Source: Eur Respir J 2006; 28: Suppl. 50, 435s
Year: 2006