e-learning
resources
Amsterdam 2011
Monday, 26.09.2011
Mechanical ventilation and lung injury: new advances
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
In vitro
performance of an improved collapsible holding chamber (CHC) for the delivery of bronchodilators to patients receiving mechanical ventilation
M. Nagel, V. Avvakoumova, R. Ali, C. Doyle, J. Mitchell (London, Canada)
Source:
Annual Congress 2011 - Mechanical ventilation and lung injury: new advances
Session:
Mechanical ventilation and lung injury: new advances
Session type:
Poster Discussion
Number:
1986
Disease area:
Airway diseases, Respiratory critical care
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
M. Nagel, V. Avvakoumova, R. Ali, C. Doyle, J. Mitchell (London, Canada).
In vitro
performance of an improved collapsible holding chamber (CHC) for the delivery of bronchodilators to patients receiving mechanical ventilation. Eur Respir J 2011; 38: Suppl. 55, 1986
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Mobile video directly observed therapy can be used to improve at-home inhaler technique in children with asthma
New inhaler devices: the good, the bad, and the ugly
Clinically appropriate testing of different valved holding chamber (VHC)-facemask combinations investigating simulated delivered mass to carina
Related content which might interest you:
In vitro
evaluation of a novel ventilation chamber (VC) for delivery of aerosolized medication to the mechanically ventilated premature infant
Source: Annual Congress 2009 - New aspects of inhalation therapy
Year: 2009
Clinical evaluation of patient ventilator asynchrony (PVA) in patients with chronic respiratory failure receiving home mechanical ventilation (HMV)
Source: Annual Congress 2010 - Noninvasive ventilation: technical, logistical and organisational aspects
Year: 2010
Comparison of response to aerosol drug delivery with mesh and jet nebulizers during non-invasive ventilation (NIV) in acute exacerbation of COPD.
Source: International Congress 2017 – Clinical and physiological challenges in noninvasive ventilation
Year: 2017
In vitro testing of an improved collapsible valved holding chamber (CHC) with a pressurized metered-dose inhaler delivered bronchodilator, simulating an adult mechanically ventilated patient
Source: Annual Congress 2010 - Treatment options for asthma
Year: 2010
A visual indicator for inhalation from a valved holding chamber (VHC) is an aid in delivery of inhaled medication to infants and small children via facemask
Source: Annual Congress 2009 - New aspects of inhalation therapy
Year: 2009
Short-term efficacy of spontaneous AVAPS (average volume assured pressure support) mask ventilation in patients with hypercapnic COPD
Source: Eur Respir J 2004; 24: Suppl. 48, 547s
Year: 2004
A comparison between adaptive support ventilation (ASV) and pressure controlled ventilation (PCV) + synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) in clinical cardiac patients under long-term mechanical ventilation
Source: Annual Congress 2007 - Mechanical ventilation and airways
Year: 2007
Influence of nebulizer type, position and bias flow on aerosol drug delivery to a pediatric model of mechanical ventilation
Source: Annual Congress 2008 - Respiratory disorders in paediatric intensive care unit
Year: 2008
The effect of entrainment site and inspiratory pressure on the delivery of oxygen therapy during non-invasive mechanical ventilation (NIMV) in acute COPD patients
Source: Eur Respir Rev 2006; 15: 190-191
Year: 2006
Increase in endotracheal tube (ETT) resistance after its use in ICU patients under mechanical ventilation (MV): forced oscillatory technique (FOT) evaluation
Source: Annual Congress 2007 - Mechanical ventilation and airways
Year: 2007
SIMVS (synchronized intermittent mandatory ventilation) mode and BCPAP (Boussignac continous positive airway pressure) system indifficult-to -wean critically ill infants from mechanical ventilation
Source: International Congress 2016 – Noninvasive ventilation and beyond: novelties and real-life applications
Year: 2016
Delivery of an HFA-formulated bronchodilator to the mechanically ventilated adult patient via holding chamber: laboratory simulation
Source: Eur Respir J 2003; 22: Suppl. 45, 473s
Year: 2003
Leak compensation in positive pressure ventilators: a lung model study
Source: Eur Respir J 2001; 17: 259-267
Year: 2001
Effect of fully-automated vs conventional ventilation on mechanical power of ventilation in COVID–19 ARDS patients
Source: Virtual Congress 2021 – COVID-19 acute respiratory distress syndrome
Year: 2021
Continuous external negative pressure ventilation (CENPV) with the chamber-ventilator - first clinical experiences in 6 intubated patients with ARDS
Source: Eur Respir J 2005; 26: Suppl. 49, 445s
Year: 2005
Impact of patient ventilator asynchrony (PVA) on the sleep quality of patients using home mechanical ventilation (HMV)
Source: International Congress 2014 – Key factors that ensure noninvasive ventilation success
Year: 2014
Telepneumology: a feasibility study for patients with chronic respiratory failure (CRF) and mechanical ventilation (MV)
Source: Annual Congress 2005 - Chronic care in respiratory failure
Year: 2005
Predicting failure of non invasive ventilation (NIV) and High flow nasal cannula (HFNC) in patients with acute hypoxemic hypocapnic respiratory failure (AHHRF): the usefulness of the standardised PaO2/FiO2 ratio (P/F-st).
Source: Virtual Congress 2020 – Non-invasive ventilation and nasal high flow: technical aspects and predictive scores
Year: 2020
Evaluation of nutritional status in patients with severe COPD treated with home mechanical ventilation (HMV)
Source: Eur Respir J 2005; 26: Suppl. 49, 84s
Year: 2005
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept