Clinical evaluation of portable oxygen concentrators: impact of pulse oxygen delivery on exercise
J. Maris (Rouen, France), B. Melloni (Limoges, France), C. Rabec (Dijon, France), J. Delrieu (Paris, France), T. Bonnevie (Rouen, France), F. Gravier (Rouen, France), F. Herengt (Dieulefit, France), Y. Al Chikahanie (Dieulefit, France), D. Foret (Paris, France), A. Chambellan (Rouen, France), J. Gonzalez-Bermerjo (Paris, France), A. Cuvelier (Rouen, France), J. Muir (Rouen, France), M. Patout (Rouen, France)
Source: Virtual Congress 2020 – New insights into determinants of patient-reported outcomes in chronic respiratory diseases
Disease area: Airway diseases
Rating:
You must login to grade this presentation.
Share or cite this content
Citations should be made in the following way:
J. Maris (Rouen, France), B. Melloni (Limoges, France), C. Rabec (Dijon, France), J. Delrieu (Paris, France), T. Bonnevie (Rouen, France), F. Gravier (Rouen, France), F. Herengt (Dieulefit, France), Y. Al Chikahanie (Dieulefit, France), D. Foret (Paris, France), A. Chambellan (Rouen, France), J. Gonzalez-Bermerjo (Paris, France), A. Cuvelier (Rouen, France), J. Muir (Rouen, France), M. Patout (Rouen, France). Clinical evaluation of portable oxygen concentrators: impact of pulse oxygen delivery on exercise. 949
You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
Related content which might interest you:
Related content which might interest you:
Comparison of pulsed flow from portable oxygen concentrators with continuous oxygen delivery. Source: International Congress 2018 – What’s new in lung function and exercise assessment in COPD? Year: 2018
Technical aspects of oxygen therapy – monitoring and devices for oxygen delivery Source: Annual Congress 2009 - Oxygen in the acute setting – new look to the indications and toxicity Year: 2009
Comparison of oxygen supplementation from portable oxygen concentrator and liquid oxygen during walk test in COPD patients on long term oxygen therapy Source: Annual Congress 2007 - Pulmonary rehabilitation beyond training Year: 2007
Assessment of portable oxygen concentrators to revert induced hypoxia by hypoxic challenge testing in paediatric patients. A comparative study between continuous flow and pulse flow delivery systems. Source: International Congress 2019 – New developments in sleep-disordered breathing, gas exchange and lung function in children Year: 2019
Does oxygen pulse trajectory during incremental exercise discriminate impaired oxygen delivery from poor muscle oxygen utilisation? Source: ERJ Open Res, 5 (2) 00108-2018; 10.1183/23120541.00108-2018 Year: 2019
Preflight hypoxia test with portable oxygen concentrators: when new technologies require more technology Source: International Congress 2016 – Man versus machine: waves, frequency, and more in lung function Year: 2016
Reliability of gas delivery when using demand oxygen delivery systems Source: Eur Respir J 2005; 26: Suppl. 49, 528s Year: 2005
Performance of a novel humidification device for high flow oxygen therapy Source: Eur Respir J 2006; 28: Suppl. 50, 189s Year: 2006
Validation of an autoadjusting device for oxygen therapy Source: Eur Respir J 2003; 22: Suppl. 45, 190s Year: 2003
A bench study evaluation of demand oxygen delivery systems Source: Annual Congress 2008 - Technologies and techniques in rehabilitation Year: 2008
Impact of automatic oxygen titration alone or with high flows on exercise tolerance in patients with lung disease and exercise oxygen desaturation Source: Virtual Congress 2020 – New insights into evaluation and treatment of respiratory disease Year: 2020
Accuracy of a novel transcutaneous combined carbon dioxide and oxygen saturation sensor in ergometry Source: Annual Congress 2007 - Exercise: measurements, techniques and paradigms Year: 2007
Modification of inspired oxygen fraction does not change exercise oxygen uptake measured by JAEGER® Vyntus CPX; a validation study Source: International Congress 2018 – Innovations in equipment and their application Year: 2018
Monitoring carbon dioxide tension and arterial oxygen saturation using TOSCA monitoring in general respiratory ward Source: Eur Respir J 2006; 28: Suppl. 50, 394s Year: 2006
Comparing the efficacy of a portable oxygen concentrator versus a liquid oxygen portable device in the promotion of physical activity and quality of life in patients with Cystic Fibrosis. Source: International Congress 2019 – Oxygen supplementation, noninvasive ventilation and mobility aspects of patients with impaired respiration Year: 2019
Prescription of oxygen therapy and nebuliser driving gas in the medical assessment unit Source: Eur Respir J 2004; 24: Suppl. 48, 229s Year: 2004
Clinical evaluation of an electronic oxygen conserving device Source: Eur Respir J 2007; 30: Suppl. 51, 571s Year: 2007
Is the initial stable value of transcutaneous oxygen/carbon dioxide monitoring equivalent to the blood gas values in oxygen assessments? Source: Eur Respir J 2007; 30: Suppl. 51, 181s Year: 2007
Portable oxygen concentrator vesus oxygen cylinder in chronic lung disease: patient preferences and psychological implications Source: Virtual Congress 2020 – Pulmonary function and rehabilitation in non-respiratory disease Year: 2020
Ambulatory oxygen: what are the must-dos and pitfalls Source: Annual Congress 2007 - Primary care: who? Where? How? Exercise testing and pulmonary rehabilitation Year: 2007