Comparison of diagnostic accuracy between the chemiluminescence and electrochemical methods for nasal nitric oxide measurements in PCD

P. Kouis (Nicosia, Cyprus), G. Chatziparasidis (Athens, Greece), B. Boutopoulou (Athens, Greece), H. Omran (Muenster, Germany), M. Kakkoura (Nicosia, Cyprus), S. Papatheodorou (Limassol, Cyprus), K. Kyriacou (Nicosia, Cyprus), M. Papadopoulos (Athens, Greece), V. Grammeniatis (Athens, Greece), K. Douros (Athens, Greece), K. Priftis (Athens, Greece), P. Yiallouros (Nicosia, Cyprus)

Source: International Congress 2018 – Insights in primary ciliary dyskinesia, asthma and lung function testing
Session: Insights in primary ciliary dyskinesia, asthma and lung function testing
Session type: Thematic Poster
Number: 4669
Disease area: Paediatric lung diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
P. Kouis (Nicosia, Cyprus), G. Chatziparasidis (Athens, Greece), B. Boutopoulou (Athens, Greece), H. Omran (Muenster, Germany), M. Kakkoura (Nicosia, Cyprus), S. Papatheodorou (Limassol, Cyprus), K. Kyriacou (Nicosia, Cyprus), M. Papadopoulos (Athens, Greece), V. Grammeniatis (Athens, Greece), K. Douros (Athens, Greece), K. Priftis (Athens, Greece), P. Yiallouros (Nicosia, Cyprus). Comparison of diagnostic accuracy between the chemiluminescence and electrochemical methods for nasal nitric oxide measurements in PCD. 4669

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Comparisons between portable and chemoluminescence exhaled nitric oxide measurements
Source: Eur Respir J 2008; 32: 243-244
Year: 2008


Comparison of exhaled nitric oxide measurements between NIOX MINO electrochemical analyzer and ecomedics chemoluminescence analyzer
Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Year: 2008


Accuracy and repeatability of a hand-held nitric oxide analyzer in adults with respiratory symptoms
Source: Eur Respir J 2005; 26: Suppl. 49, 572s
Year: 2005

A comparison of two analysers measuring exhaled nitric oxide concentration
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

The accuracy of nasal nitric oxide testing in PCD diagnostics is population specific
Source: International Congress 2015 – Highlights in paediatric epidemiology: air pollution, asthma and primary ciliary dyskinesia
Year: 2015


Reproducibility of the Vivatmopro measurements for exhaled nitric oxide values
Source: International Congress 2019 – Insights into physiological diagnostic services
Year: 2019


Correction equation to compare exhaled nitric oxide measured by a portable analyzer to that obtained by the gold-standard device
Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Year: 2008


Feasibility and repeatability of fractional exhaled nitric oxide (FENO) measurements using a new hand-held NO monitoring device in general practice
Source: Eur Respir J 2006; 28: Suppl. 50, 791s
Year: 2006

The agreement between online and offline measurement of exhaled nitric oxide
Source: Eur Respir J 2001; 18: Suppl. 33, 39s
Year: 2001

Comparison of exhaled nitric oxide values measured by two offline methods or NO breath
Source: Annual Congress 2013 –Systemic and airway biomarkers in respiratory diseases
Year: 2013


Measurement of exhaled nitric oxide: comparison of 3 different analyzers
Source: International Congress 2018 – Biomarkers for evaluating asthma
Year: 2018

Intra-device repeatability of the NIOX-MINO handheld fractional exhaled nitric oxide monitor.
Source: International Congress 2019 – Asthma biomarkers, diagnostics and risk factors
Year: 2019


Early detection of emphysema with the nitric oxide diffusion capacity
Source: Eur Respir J 2007; 30: Suppl. 51, 8s
Year: 2007

The feasibility of nitric oxide measurements at various flow rates in children with asthma
Source: Eur Respir J 2006; 28: Suppl. 50, 257s
Year: 2006

Technical problems with measurements of biomarkers - exhaled nitric oxide
Source: ERS Skills course - Biomarkers and functional assessment of obstructive lung diseases
Year: 2017

Reliability of a new portable device for the measurement of fractional exhaled nitric oxide (FeNO)
Source: Annual Congress 2010 - Innovations in the assessment of airway diseases
Year: 2010


Reproducibility of exhaled nitric oxide (NO) measured by multiple exhalation flow technique (MEFT) in adults
Source: Eur Respir J 2003; 22: Suppl. 45, 279s
Year: 2003

Effective patient selection for PCD diagnostics; the PICADAR score with nasal nitric oxide
Source: International Congress 2016 – Highlights in primary ciliary dyskinesia and asthma in childhood
Year: 2016


Effect of a sequential exhalation flow method on exhaled nitric oxide measurements
Source: Eur Respir J 2004; 24: Suppl. 48, 340s
Year: 2004