Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects

Joanna C. Watts, Claude S. Farah, Leigh M. Seccombe, Blake M. Handley, Robin E. Schoeffel, Amy Bertolin, Jessica Dame Carroll, Gregory G. King, Cindy Thamrin

Source: ERJ Open Res 2016: 00094-2015
Journal Issue: June
Disease area: Airway diseases

Congress or journal article abstractFull text journal articlePDF journal article, handout or slides

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Joanna C. Watts, Claude S. Farah, Leigh M. Seccombe, Blake M. Handley, Robin E. Schoeffel, Amy Bertolin, Jessica Dame Carroll, Gregory G. King, Cindy Thamrin. Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects. ERJ Open Res 2016: 00094-2015

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Short term intra-individual variability of respiratory resistance measured by forced oscillation technique in healthy adults and adults with obstructive airway diseases
Source: International Congress 2019 – Insights into physiological diagnostic services
Year: 2019


Relationship between lung function using forced oscillation technique (FOT) with recent symptoms in young children with asthma
Source: Annual Congress 2011 - Advances in lung function testing from infancy to adulthood
Year: 2011


Long-term change in reactance by forced oscillation technique correlates with FEV1decline in moderate COPD patients
Source: Eur Respir J , 49 (4)  1601534; DOI: 10.1183/13993003.01534-2016
Year: 2017



Evaluation of respiratory impedance in asthma and COPD by forced oscillation technique using a MostGraph
Source: Annual Congress 2010 - Advances in lung function I
Year: 2010


The ratio of inspiratory ΣRrs to expiratory ΣRrs measured by forced oscillation technique correlates with the parameters reflecting narrowing of small airway measured by spirometry in patients with mild to moderate COPD
Source: Annual Congress 2013 –New issues in lung function testing
Year: 2013

Bronchodilator response in healthy adult subjects assessed with the forced oscillation technique
Source: Eur Respir J 2004; 24: Suppl. 48, 577s
Year: 2004

The use of forced oscillation technique (FOT) in assessment and stratification of disease severity in elderly COPD patients
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011


Bronchodilator response in healthy adults assessed with the forced oscillation technique and spirometry
Source: Annual Congress 2009 - New data on respiratory function - from experimental approaches to man
Year: 2009

Variability of forced oscillation technique and correlation with spirometry in adults
Source: Eur Respir J 2004; 24: Suppl. 48, 575s
Year: 2004

Evaluation of respiratory impedance in COPD by forced oscillation technique using a MostGraph
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011

Comparison of forced oscillation technique and spirometry in paediatric asthma
Source: ERJ Open Res, 7 (1) 00202-2020; 10.1183/23120541.00202-2020
Year: 2021



Duration and frequency of spirometry needed to accurately reflect longitudinal change of FEV1 in COPD
Source: Virtual Congress 2021 – Lung function testing in the management of obstructive diseases
Year: 2021


Different breathing strategies during inspiratory loads in healthy persons and in COPD patients assessed by a noninvasive EMG technique
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

Effect of different mask design for measuring respiratory input impedance in pre-school children by forced oscillation technique (FOT)
Source: International Congress 2017 – Best abstracts in lung function
Year: 2017



The use of forced oscillation technique (FOT) in assessment of airway obstruction and airtrapping in elderly COPD patients
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011


Repeatability study comparing plethysmographic and spirometric lung function parameters in COPD patients, asthmatics, and healthy subjects
Source: Eur Respir J 2006; 28: Suppl. 50, 221s
Year: 2006

The effect of shift work on serial peak expiratory flow measurements used for diagnosing occupational asthma
Source: Annual Congress 2010 - Occupational asthma
Year: 2010

Broadband forced oscillations in healthy and COPD subjects: the impact of velum position
Source: Annual Congress 2008 - Assessment of the respiratory system
Year: 2008

Changes in respiratory resistance of mild asthmatic children after administraton of a bronchodilator measured by the forced oscillation technique
Source: Annual Congress 2004 - Airway resistance: application and technique
Year: 2004


Diurnal variation and serial changes of peak expiratory flow in adult patients with cough variant asthma
Source: Eur Respir J 2004; 24: Suppl. 48, 588s
Year: 2004