e-learning
resources
Stockholm 2007
Sunday 16.09.2007
Assessing the airways: innovation, applications and pitfalls
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
The frequency content of the maximum forced expiratory manoeuvre
M. Miller (Birmingham, United Kingdom)
Source:
Annual Congress 2007 - Assessing the airways: innovation, applications and pitfalls
Session:
Assessing the airways: innovation, applications and pitfalls
Session type:
Thematic Poster Session
Number:
1116
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
M. Miller (Birmingham, United Kingdom). The frequency content of the maximum forced expiratory manoeuvre. Eur Respir J 2007; 30: Suppl. 51, 1116
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Panel discussion: Diagnostic tools for Obstructive Sleep Apnoea in adults and children
Expert interview: Physiological classification of lung function impairment
Occupational exposures to respiratory diseases: A case-based discussion
Related content which might interest you:
Recording flow in the first second of a maximal forced expiratory manoeuvre: influence of frequency content
Source: Eur Respir J 2002; 19: 530-533
Year: 2002
Does negative expiratory pressure (NEP) influence the performances of forced expiratory manoeuvres in elderly patient?
Source: Eur Respir J 2002; 20: Suppl. 38, 32s
Year: 2002
An investigation into the usefulness of combined relaxed inspiratory and expiratory vital capacities in expiratory flow limitation
Source: Eur Respir J 2004; 24: Suppl. 48, 403s
Year: 2004
Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?
Source: Eur Respir J 2006; 27: 1244-1250
Year: 2006
Influence of postural pattern during nebulization using broncodilators drugs on the maximal inspiratory pressure(MIP), maximal expiratory pressure (MEP) and peak expiratory flow (PEF) in asmathic children
Source: Eur Respir J 2004; 24: Suppl. 48, 407s
Year: 2004
Forced expiratory manoeuvres
Source: Eur Respir Mon; 2010: 47: 46–65
Year: 2010
Does negative expiratory pressure influence performances of spirometry in older patients?
Source: Eur Respir J 2002; 20: 674-678
Year: 2002
Is forced expiratory volume in six seconds a valid alternative to forced vital capacity?
Source: Eur Respir J 2006; 28: 1288-1289
Year: 2006
Sources of variation in forced expiratory volume in one second and forced vital capacity
Source: Eur Respir J 2006; 27: 767-773
Year: 2006
Forced vital capacity and forced expiratory volume in six seconds as predictors of reduced total lung capacity
Source: Eur Respir J 2008; 31: 391-395
Year: 2008
Exercise test results and forced expiratory flow rates at low lung volumes
Source: Eur Respir J 2002; 20: Suppl. 38, 286s
Year: 2002
Obstructive ventilatory defect with normal forced expiratory volume in one second/vital capacity ratio
Source: Eur Respir J 2006; 27: 1069-1070
Year: 2006
The type of mouthpiece used affects the peak expiratory flow
Source: Annual Congress 2003 - Assessing airway function: practicalities and clinical applications
Year: 2003
Maximal inspiratory and expiratory pressure measurement in tracheotomised patients
Source: Eur Respir J 2006; 27: 343-349
Year: 2006
Reproducibility in parameters of forced inspiratory flow
Source: Annual Congress 2009 - Functional insights into COPD
Year: 2009
Predicted values for the forced expiratory flow adjusted for forced vital capacity, a descriptive study
Source: ERJ Open Res, 6 (4) 00426-2020; 10.1183/23120541.00426-2020
Year: 2020
Can the prediction point for FEV1 / FVC be determined in patients with insufficient expiratory maneuver to determine airflow obstruction?
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020
Is the forced expiratory volume in 6 seconds (FEV
6
) a more reproducible and accurate measurement than forced vital capacity (FVC) in obstructive and normal/restrictive patients
Source: Eur Respir J 2001; 18: Suppl. 33, 13s
Year: 2001
Managing COPD with expiratory or inspiratory pressure load training based on a prolonged expiration pattern
Source: ERJ Open Res, 6 (3) 00041-2020; 10.1183/23120541.00041-2020
Year: 2020
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept