Improvement of FRC analysis from ultrasonic flow measurements in infants by optimised temperature and deadspace correction

P. Latzin, A. Schibler, J. G. Hutten, T. Riedel, U. Frey (Bern, Switzerland; Brisbane, Australia)

Source: Annual Congress 2006 - Diagnostic paediatric lung function: technical and clinical aspects
Session: Diagnostic paediatric lung function: technical and clinical aspects
Session type: Thematic Poster Session
Number: 4057
Disease area: Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
P. Latzin, A. Schibler, J. G. Hutten, T. Riedel, U. Frey (Bern, Switzerland; Brisbane, Australia). Improvement of FRC analysis from ultrasonic flow measurements in infants by optimised temperature and deadspace correction. Eur Respir J 2006; 28: Suppl. 50, 4057

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
In vitro assessment of an ultrasonic airflow meter for FRC measurements in newborns
Source: Eur Respir J 2001; 18: Suppl. 33, 346s
Year: 2001

The noise of an ultrasound flowmeter does not affect tidal volume and FRC measurements in infants
Source: Eur Respir J 2003; 22: Suppl. 45, 128s
Year: 2003

Measurement of functional residual capacity (FRC) determined by gas dilution in infants using an ultrasonic flowmeter and a sulphur-hexafluoride (SF6) washin/washout technique
Source: Eur Respir J 2001; 18: Suppl. 33, 117s
Year: 2001

Comparison of flow-volume measurements with realtime versus fixed temperature BTPS correction
Source: Annual Congress 2013 –Expiration, exhalation and exhaustion: measures of dynamic volumes, breath analysis and respiratory muscles
Year: 2013


Measurements of forced expiratory flows and volumes in intubated monkeys: pneumotachograph versus ultrasonic flow meter
Source: Eur Respir J 2003; 22: Suppl. 45, 128s
Year: 2003

Measurement of tidal breathing flows in infants using impedance pneumography
Source: Eur Respir J , 49 (2) 1600926; DOI: 10.1183/13993003.00926-2016
Year: 2017



Measurement of functional residual capacity (FRC) in infants and young children using an ultrasonic flowmeter for SF6 multiple breath washing/washout
Source: Eur Respir J 2002; 20: Suppl. 38, 19s
Year: 2002

Reproducibility and repeatability of tidal breathing parameters derived from structured light plethysmography when compared to spirometry
Source: Annual Congress 2011 - Lung and airway function
Year: 2011


Validation of the assessment of flow limitation at rest by overlapping of the tidal and maximal flow volume curves
Source: Annual Congress 2009 - Quality control in lung function and new developments
Year: 2009


Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer
Source: Eur Respir J 2004; 23: 763-768
Year: 2004



Inert gas rebreathing: the effect of pulmonary shunt flow correction on the accuracy of cardiac output measurements in clinical practice
Source: Annual Congress 2009 - Pulmonary vascular diseases
Year: 2009

Assessment of inhaler technique using inspiratory flow measurement
Source: Annual Congress 2007 - Miscellaneous pulmonary pharmacology II
Year: 2007


Accuracy of a portable system for DLCO measurement using ultrasonic flow and molar mass measurement
Source: Eur Respir J 2006; 28: Suppl. 50, 422s
Year: 2006

Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Source: Eur Respir J 2002; 20: 912-918
Year: 2002



A new method for measuring FRC by gas washout in respirated infants after cardiac surgery
Source: Eur Respir J 2001; 18: Suppl. 33, 456s
Year: 2001

Pneumotachographic volume and leak measurements during CPAP in neonates
Source: Annual Congress 2008 - Neonatal intensive care: ventilation and beyond
Year: 2008

Volume acceleration profile in expiratory flow limitation during mechanical ventilation
Source: Eur Respir J 2001; 18: Suppl. 33, 480s
Year: 2001

A novel technique “slow spirometry” to estimate tidal volumes for use in AVAPS mode ventilation in children.
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020


Influence of mask leak on applied volumes and pressures during simulated resuscitation of neonates
Source: Annual Congress 2011 - Resuscitation and ventilation in the baby and infant
Year: 2011

Impact of leakage on external flow measurement in non-invasive ventilation
Source: Annual Congress 2012 - Recent technical developments in long-term noninvasive ventilation
Year: 2012