Optimising estimation of respiratory tract lining fluid dilution in exhaled breath condensate using conductivity measurements

C. Wells, S. Akunuri, N. Clark, E. Baker (London, United Kingdom)

Source: Annual Congress 2007 - Noninvasive evaluation of airway diseases
Session: Noninvasive evaluation of airway diseases
Session type: Electronic Poster Discussion
Number: 524
Disease area: Airway diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
C. Wells, S. Akunuri, N. Clark, E. Baker (London, United Kingdom). Optimising estimation of respiratory tract lining fluid dilution in exhaled breath condensate using conductivity measurements. Eur Respir J 2007; 30: Suppl. 51, 524

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Changes in ventilation and respiratory impedance after sampling of exhaled breath condensate (EBC) in pigs
Source: Eur Respir J 2002; 20: Suppl. 38, 175s
Year: 2002

Effect of varying respiratory pattern on exhaled breath condensate collection
Source: Eur Respir J 2003; 22: Suppl. 45, 37s
Year: 2003

Separate lung exhaled breath condensate collection confirms intrapulmonary origin of exhaled breath condensate acidification
Source: Eur Respir J 2007; 30: Suppl. 51, 364s
Year: 2007

Inner coating of condenser systems influences detection of albumin in exhaled breath condensate
Source: Eur Respir J 2003; 22: Suppl. 45, 280s
Year: 2003

Influence of breathing pattern on exhaled breath condensate collection
Source: Eur Respir J 2002; 20: Suppl. 38, 174s
Year: 2002

Comparison of two devices and two breathing patterns for exhaled breath condensate sampling
Source: Annual Congress 2011 - Bronchial hyperresponsiveness and exhaled and sputum biomarkers
Year: 2011

Measurement of surfactant phospholipids in exhaled breath condensate
Source: Annual Congress 2008 - Investigation, inspiration, ventilation, dedication: the essence of physiological measurement
Year: 2008

Possible use of exhaled breath condensate (EBC) for continuous monitoring of lung inflammation in artificial ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

The coating of condenser systems influences the detection of 8-isoprostane in exhaled breath condensate (EBC)
Source: Eur Respir J 2004; 24: Suppl. 48, 468s
Year: 2004

pH measurement in exhaled breath condensate: a comparison between two collection devices
Source: Eur Respir J 2006; 28: Suppl. 50, 790s
Year: 2006

Validation of eicosanoid measurements in exhaled breath condensate
Source: Eur Respir J 2002; 20: Suppl. 38, 422s
Year: 2002

The influence of active and passive air humidification on exhaled breath condensate volume
Source: ERJ Open Res, 6 (4) 00009-2020; 10.1183/23120541.00009-2020
Year: 2020



Rapid measurement of lactate in exhaled breath condensate
Source: Eur Respir J 2006; 28: Suppl. 50, 435s
Year: 2006

Mathematic model of exhaled breath condensate forming
Source: Eur Respir J 2006; 28: Suppl. 50, 422s
Year: 2006

Exhaled breath condensate pH standardised for CO2 partial pressure
Source: Eur Respir J 2007; 29: 496-501
Year: 2007



The effect of gas standardisation on exhaled breath condensate pH
Source: Eur Respir J 2006; 28: 251-252
Year: 2006


Electrical conductivity, pH and ammonia in exhaled breath condensate (EBC) from patients with different airway disorders
Source: Eur Respir J 2006; 28: Suppl. 50, 790s
Year: 2006

Continuous exhaled breath condensate pH monitoring
Source: Eur Respir J 2004; 24: Suppl. 48, 27s
Year: 2004

Parameters of oxidation in exhaled breath condensate
Source: Eur Respir J 2004; 24: Suppl. 48, 470s
Year: 2004