Recommended approaches to minimize aerosol dispersion of COVID during noninvasive ventilatory support can deteriorate ventilator performances: a benchmark comparative study

M. Patout (Paris, France), E. Fresnel (Bois-Guillaume, France), M. Lujan (Barcelona, Spain), C. Rabec (Mont-Saint Aignan, France), A. Carluci (Mont-Saint Aignan, France), L. Razakamanantsoa (Rouen, France), A. Kerfourn (Bois-Guillaume, France), H. Nunes (Bobigny, France), Y. Tandjaoui-Lambiotte (Bobigny, France), A. Cuvelier (Rouen, France), J. Muir (Rouen, France), C. Lalmoda (Barcelona, Spain), B. Langevin (Alès, France), J. Sayas (Madrid, Spain), J. Gonzalez-Bermejo (Paris, France), J. Janssens (Geneva, Switzerland)

Source: Virtual Congress 2021 – New trends in non-invasive respiratory support
Session: New trends in non-invasive respiratory support
Session type: Oral Presentation
Number: 1629

Congress or journal article abstractWebcastSlide presentation

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
M. Patout (Paris, France), E. Fresnel (Bois-Guillaume, France), M. Lujan (Barcelona, Spain), C. Rabec (Mont-Saint Aignan, France), A. Carluci (Mont-Saint Aignan, France), L. Razakamanantsoa (Rouen, France), A. Kerfourn (Bois-Guillaume, France), H. Nunes (Bobigny, France), Y. Tandjaoui-Lambiotte (Bobigny, France), A. Cuvelier (Rouen, France), J. Muir (Rouen, France), C. Lalmoda (Barcelona, Spain), B. Langevin (Alès, France), J. Sayas (Madrid, Spain), J. Gonzalez-Bermejo (Paris, France), J. Janssens (Geneva, Switzerland). Recommended approaches to minimize aerosol dispersion of COVID during noninvasive ventilatory support can deteriorate ventilator performances: a benchmark comparative study. 1629

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
A comparison of two methods of noninvasive ventilatory support in weaning from mechanical ventilation
Source: Annual Congress 2009 - New trends in noninvasive ventilation for acute respiratory failure
Year: 2009


Preliminary study of a noninvasive bilevel ventilator algorithm for the automatic adjustment of pressure support, respiratory rate and cycling
Source: Eur Respir J 2005; 26: Suppl. 49, 444s
Year: 2005

Noninvasive ventilation is better than oxygen supplementation to improve performance during a physical training program in COPD patients-A randomized study
Source: Annual Congress 2010 - What's new in pulmonary rehabilitation and chronic care in 2010
Year: 2010

The amount of intentional leaks in masks significantly impacts on bi-level non-invasive ventilation efficacy: a bench test study
Source: Annual Congress 2007 - Technological progress in noninvasive ventilation
Year: 2007



Patient-ventilator interaction during noninvasive ventilation: practical assessment and theoretical basis
Source: Breathe 2009; 5: 322-333
Year: 2009


Bench study evaluation of ventilator behavior with different humidification conditions during noninvasive home ventilation
Source: International Congress 2019 – Hot topics in noninvasive ventilation
Year: 2019


Effect of non-linear leaks on the monitoring accuracy of home mechanical ventilators: A bench study
Source: Annual Congress 2013 –Long-term NIV: children, neuromuscular patients and technical aspects
Year: 2013


Evaluating noninvasive ventilation using a monitoring system coupled to a ventilator: a bench-to-bedside study
Source: Eur Respir J 2009; 34: 902-913
Year: 2009



A novel simple internet-based system for real time monitoring and optimizing home mechanical ventilation
Source: Annual Congress 2008 - Noninvasive ventilation in the chronic setting
Year: 2008

How to optimise mechanical ventilation: interpretation of waveforms
Source: Annual Congress 2009 - MP3 - How to optimise mechanical ventilation: interpretation of waveforms
Year: 2009

Assessment of two different methods of bronchodilators delivery during noninvasive ventilation. Experimental in vivo approach
Source: Eur Respir J 2004; 24: Suppl. 48, 315s
Year: 2004

Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing
Source: Eur Respir J, 55 (6) 2000846; 10.1183/13993003.00846-2020
Year: 2020



Monitoring exhaled oxygen concentration during mechanical ventilation: a novel approach for bedside estimation of ventilation heterogeneities
Source: International Congress 2017 – Evaluating lung function, dyspnoea and related respiratory diseases
Year: 2017

iVAPS (intelligent volume assured pressure support) for non-invasive ventilation - a case-control study
Source: International Congress 2014 – Key factors that ensure noninvasive ventilation success
Year: 2014


Optimizing NIV: assesment of a ventilatory monitoring system integrated to a portable ventilator
Source: Eur Respir J 2004; 24: Suppl. 48, 476s
Year: 2004

Upper airway assessment to optimise non-invasive ventilation and cough assist device use
Source: Sleep and Breathing Conference 2021
Year: 2021

LATE-BREAKING ABSTRACT: A parametric procedure to compare domiciliary ventilator performances
Source: International Congress 2015 – Noninvasive ventilation in acute respiratory failure: the recipe for success
Year: 2015



Optimization of ventilator setting by flow and pressure curves analysis in noninvasive ventilation for acute exacerbations of COPD: Preliminary results
Source: Annual Congress 2010 - News from noninvasive ventilation
Year: 2010

Using a breathing simulator to improve simulation-based education for noninvasive ventilation
Source: Breathe, 17 (2) 200285; 10.1183/20734735.0285-2020
Year: 2021



The NIVO score: can it help to improve noninvasive ventilation in daily clinical practice?
Source: Eur Respir J, 58 (2) 2100336; 10.1183/13993003.00336-2021
Year: 2021