Late Breaking Abstract - High volume, low PEEP and passive hyperventilation without sedatives instead of low tidal volume, high PEEP and deep sedation in COVID19.

G. Laier-Groeneveld (Göttingen, Germany), B. Kurz (Neustadt, Harz, Germany), C. Criée (Göttingen, Germany), G. Hasenfuß (Göttingen, Germany)

Source: Virtual Congress 2020 – Novel findings regarding acute respiratory distress syndrome, extra corporeal membrane oxygenation and weaning from mechanical ventilation
Disease area: Respiratory critical care

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
G. Laier-Groeneveld (Göttingen, Germany), B. Kurz (Neustadt, Harz, Germany), C. Criée (Göttingen, Germany), G. Hasenfuß (Göttingen, Germany). Late Breaking Abstract - High volume, low PEEP and passive hyperventilation without sedatives instead of low tidal volume, high PEEP and deep sedation in COVID19.. 3431

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Pattern of breathing (frequency and tidal volume) influences level and interpretation of exercise ventilation in childhood
Source: Eur Respir J 2007; 30: Suppl. 51, 324s
Year: 2007

2nd prize: Impact of positive end-expiratory pressure on functional residual capacity and ventilation in children exposed to high levels of inspired oxygen
Source: Annual Congress 2007 - Paediatric Respiratory Research Award
Year: 2007


Use of low tidal volume ventilation (LTVV) has an association with outcome in COVID-19 patients
Source: Virtual Congress 2021 – COVID-19 acute respiratory distress syndrome
Year: 2021



High levels of inspired oxygen impair functional residual capacity and ventilation distribution in anaesthetised preschool children – can it be avoided by PEEP?
Source: Annual Congress 2006 - New developments in infant and intensive care lung function
Year: 2006


Positive end-expiratory pressure and tidal volume titration after recruitment maneuver(RM) in ARDS--an animal study
Source: Eur Respir J 2004; 24: Suppl. 48, 265s
Year: 2004

Physiological value of expiratory pause in one-lung high frequency jet ventilation
Source: International Congress 2016 – Diagnostic and therapeutic challenges in acute respiratory failure
Year: 2016


Influence of end-expiratory level and tidal volume on ventilation distribution
Source: Annual Congress 2011 - Innovative methods in clinical physiology
Year: 2011

SHFJV (super imposed high frequency jet ventilation), ETCO2 correlation to PaCO2 in diagnostic and therapeutic rigid bronchosscopy
Source: Annual Congress 2011 - To stent or not to stent: interventional bronchoscopy
Year: 2011

Relationship between peak inspiratory pressure and tidal volume during mechanical ventilation in ARDS
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

Mean, peak airway pressure and PEEP during mechanical ventilation
Source: Eur Respir J 2003; 22: Suppl. 45, 189s
Year: 2003

The effect of mouth leak on tidal volume during non-invasive ventilation
Source: Annual Congress 2003 - Physiology of NIV: understanding the effects and chosing the best settings
Year: 2003


Measurement of end-expiratory lung volume by a bag-in-box system during pressure support ventilation
Source: Eur Respir J 2005; 26: Suppl. 49, 89s
Year: 2005

Peak inspiratory pressure as a function of respiratory mechanics, tidal volume and breathing frequency during mechanical ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 602s
Year: 2002

Effects of nebulization with heliox coupled with positive end-expiratory pressure on the regional chest wall volume variations: A clinical trial
Source: Annual Congress 2011 - Asthma: issues in rehabilitation and physical therapy
Year: 2011

Autotitrating external positive end-expiratory airway pressure to abolish expiratory flow limitation during tidal breathing in patients with severe COPD: a physiological study
Source: Eur Respir J, 56 (3) 1902234; 10.1183/13993003.02234-2019
Year: 2020



Triggered mode, work of breathing and volume guarantee level during neonatal ventilation
Source: Eur Respir J 2007; 30: Suppl. 51, 395s
Year: 2007

Which is the best tidal volume in one-lung ventilation?
Source: Eur Respir J 2002; 20: Suppl. 38, 284s
Year: 2002

LATE-BREAKING ABSTRACT: Automatic tailoring of positive end-expiratory pressure (PEEP) by forced oscillation technique (FOT) during non-invasive ventilation: Effects of posture and exertion in COPD
Source: Annual Congress 2012 - Advanced experience with long-term noninvasive ventilation and late-breaking abstracts
Year: 2012

Dynamic hyperinflation in COPD: influence of measuring technique, breathing frequency and tidal volume
Source: Eur Respir J 2007; 30: Suppl. 51, 340s
Year: 2007

Noninvasive ventilation: modes of ventilation
Source: ISSN=1025-448x, ISBN=1-904097-17-0, page=67
Year: 2001