Respiratory rate and tidal volume interaction among Venturi mask kits used at hospital settings: an in vitro study.

A. Pagliocchi (São Paulo, Brazil), J. Jardim (São Paulo, Brazil), L. Chiavegato (São Paulo, Brazil), J. Bonassa (São Paulo, Brazil), I. Santoro (São Paulo, Brazil)

Source: Virtual Congress 2020 – Physiotherapy in acute respiratory care
Session: Physiotherapy in acute respiratory care
Session type: E-poster session
Number: 3019
Disease area: Respiratory critical care

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. Pagliocchi (São Paulo, Brazil), J. Jardim (São Paulo, Brazil), L. Chiavegato (São Paulo, Brazil), J. Bonassa (São Paulo, Brazil), I. Santoro (São Paulo, Brazil). Respiratory rate and tidal volume interaction among Venturi mask kits used at hospital settings: an in vitro study.. 3019

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Inspired oxygen fraction during non-invasive ventilation: the influence of flow rates, masks, exhalation ports and ventilatory settings
Source: International Congress 2018 – Non-invasive ventilation in chronic respiratory failure
Year: 2018


Accuracy of ventilators for intermediate care to deliver tidal volume. A bench study
Source: International Congress 2015 – Acute critical care: novelties in critical care
Year: 2015


Tidal volume, recruitment and compliance in HFOV: same principles, different frequency
Source: Eur Respir J 2012; 40: 291-293
Year: 2012


A novel technique “slow spirometry” to estimate tidal volumes for use in AVAPS mode ventilation in children.
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020


Do predicted tidal volumes have value in setting up domiciliary non-invasive ventilation?
Source: International Congress 2018 – Innovations in equipment and their application
Year: 2018




Use of low tidal volume ventilation (LTVV) has an association with outcome in COVID-19 patients
Source: Virtual Congress 2021 – COVID-19 acute respiratory distress syndrome
Year: 2021



Increase in endotracheal tube (ETT) resistance after its use in ICU patients under mechanical ventilation (MV): forced oscillatory technique (FOT) evaluation
Source: Annual Congress 2007 - Mechanical ventilation and airways
Year: 2007


Positive end-expiratory pressure and tidal volume titration after recruitment maneuver(RM) in ARDS--an animal study
Source: Eur Respir J 2004; 24: Suppl. 48, 265s
Year: 2004

The impact of downsizing the trachestomy tube on tidal volume and work of breathing: a bench study
Source: Eur Respir J 2005; 26: Suppl. 49, 87s
Year: 2005

Tidal volume and breathing rate – changing relationships during domicilary ventilation?
Source: Eur Respir J 2007; 30: Suppl. 51, 720s
Year: 2007

How do mechanical insufflation:exsufflation (MI:E) settings influence flow rates and sputum movement? A bench study using a paediatric lung model
Source: International Congress 2014 – Assessment and techniques of physiotherapy: from healthy subjects to critical patients
Year: 2014


Variability of tidal volume in assisted mechanical ventilation in ARDS: a bench study
Source: International Congress 2017 – New insights into acute critical care
Year: 2017

Leak compensation in positive pressure ventilators: a lung model study
Source: Eur Respir J 2001; 17: 259-267
Year: 2001



Disruption of tidal breathing in COPD by use of pneumotachograph and mouthpiece compared to non-contact measurement with structured light plethysmography (SLP)
Source: International Congress 2015 – Functional and imaging techniques for assessing lung, airway and respiratory muscles
Year: 2015

Performance of ventilators for noninvasive positive-pressure ventilation in children
Source: Eur Respir J 2008; 31: 1300-1307
Year: 2008



Automatic regulation of tidal volume and respiratory rate in intubated patients based on lung mechanics
Source: Eur Respir J 2003; 22: Suppl. 45, 443s
Year: 2003

Triggered mode, work of breathing and volume guarantee level during neonatal ventilation
Source: Eur Respir J 2007; 30: Suppl. 51, 395s
Year: 2007

The effects of pressurization rate on breathing pattern, work of breathing, gas exchange and patient comfort in pressure support ventilation
Source: Eur Respir J 2001; 18: 107-114
Year: 2001



High-flow nasal cannula heated-humidified (HFNC) oxygen (O2) at 2 litres (lt)/kg/min versus low-flow O2 (up to 2lt/min) in pediatric emergency department (PED) and pediatric ward (PW) in infants with bronchiolitis who need O2 administration: A combined prospective randomized controlled and retrospective study: Preliminary results
Source: International Congress 2015 – Outcome of noninvasive ventilatory support in acute and chronic respiratory failure
Year: 2015


Effects of patient ventilator asynchrony (PVA) on gas exchange, respiratory muscle load, patient comfort and adherence to non-invasive ventilation (NIV)
Source: Annual Congress 2013 –New evidence for NIV in the chronic setting
Year: 2013