Closed loop automated oxygen control in optimisation of mechanical ventilation in preterm infants

H. Ambulkar (London, United Kingdom), S. Sturrock (London, United Kingdom), S. Sweeney (London, United Kingdom), N. Bednarczuk (London, United Kingdom), E. Williams (London, United Kingdom), T. Dassios (London, United Kingdom), A. Greenough (London, United Kingdom)

Source: Virtual Congress 2020 – Neonatal and paediatric intensive care: diagnosis, management and outcomes
Session: Neonatal and paediatric intensive care: diagnosis, management and outcomes
Session type: E-poster session
Number: 2820
Disease area: Paediatric lung diseases, Respiratory critical care

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
H. Ambulkar (London, United Kingdom), S. Sturrock (London, United Kingdom), S. Sweeney (London, United Kingdom), N. Bednarczuk (London, United Kingdom), E. Williams (London, United Kingdom), T. Dassios (London, United Kingdom), A. Greenough (London, United Kingdom). Closed loop automated oxygen control in optimisation of mechanical ventilation in preterm infants. 2820

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Evolution of tidal volume requirements during the neonatal period in preterm infants supported by pressure limited ventilation
Source: International Congress 2017 – NICU/ PICU: evaluating short- and long-term ventilatory management
Year: 2017

Feasibility of assessing ventilation inhomogeneity by volumetric capnography during resuscitation of preterm infants
Source: Virtual Congress 2021 – Respiratory disorders in neonatal and paediatric intensive care
Year: 2021



Forced oscillation technique for optimising PEEP in ventilated extremely preterm infants
Source: Eur Respir J, 55 (5) 1901650; 10.1183/13993003.01650-2019
Year: 2020



Volume targeted versus pressure limited ventilation in term born infants
Source: International Congress 2015 – Neonatal and paediatric intensive care
Year: 2015


Biphasic (BiLevel) versus assist-control ventilation in preterm lambs
Source: Eur Respir J 2007; 30: Suppl. 51, 394s
Year: 2007

Analysis of ventilation and hemodynamic changes resulting from noninvasive bilevel pressure mechanical ventilation applied to newborn with acute pneumonia
Source: Annual Congress 2009 - Respiratory disorders of the newborn
Year: 2009

Comparisons of predictive performance of breathing pattern variabilities measured during T-piece, automatic tube compensation and pressure support ventilation for weaning ICU patients from mechanical ventilation
Source: Annual Congress 2011 - Mechanical ventilation and lung injury: new advances
Year: 2011

Recommendations for mechanical ventilation in preterms
Source: Respiratory Failure and Mechanical Ventilation Conference 2020
Year: 2020


Effect of positioning on ventilation distribution in preterm infants
Source: Annual Congress 2008 - Respiratory physiology in health and disease
Year: 2008

Non-invasive monitoring of respiratory mechanics during high frequency oscillatory ventilation (HFOV) in infant RDS
Source: Eur Respir J 2005; 26: Suppl. 49, 668s
Year: 2005

Time course of invasive positive-pressure mechanical ventilation in infants
Source: Eur Respir J 2002; 20: Suppl. 38, 533s
Year: 2002

Reliability of PEEP in neonatal resuscitation – comparison of two common ventilation devices
Source: Annual Congress 2008 - Neonatal intensive care: ventilation and beyond
Year: 2008

Lung derecruitment related to endotracheal suction in ventilated preterm infants
Source: Annual Congress 2010 - Paediatric and neonatal intensive care
Year: 2010

Prediction of successful weaning from mechanical ventilation by continuous ultrasound monitoring of diaphragm excursion
Source: Virtual Congress 2021 – Respiratory failure in COVID19 and beyond
Year: 2021


Spontaneous respiratory activity during mechanical ventilation of term born infants
Source: Annual Congress 2011 - Issues in paediatric and neonatal intensive care
Year: 2011

SIMVS (synchronized intermittent mandatory ventilation) mode and BCPAP (Boussignac continous positive airway pressure) system indifficult-to -wean critically ill infants from mechanical ventilation
Source: International Congress 2016 – Noninvasive ventilation and beyond: novelties and real-life applications
Year: 2016

Tidal volumes and ETCO2 levels during resuscitation and prematurely born infants’ outcomes
Source: International Congress 2016 – Neonatal and paediatric multiorgan manifestations of acute and chronic pulmonary disease and use of treatments
Year: 2016

Noninvasive ventilation in infants and children
Source: International Congress 2016 – Paediatric Year in Review
Year: 2016


Home monitoring of transcutaneous PCO2 in children on long term ventilation.
Source: International Congress 2018 – Non-invasive ventilation in chronic respiratory failure
Year: 2018

Efects of non-invasive respiratory support (nCPAP or nBiPAP) application following extubation in preterm babies
Source: International Congress 2019 – Neonatal and paediatric intensive care
Year: 2019