Reference values for pH and nitrosative stress parameters in exhaled breath condensate: impact of age

M. J. Cruz, S. Sanchez-Vidaurre, X. Muñoz, M. A. Ramón, L. Ruano, F. Morell (Barcelona, Spain)

Source: Annual Congress 2007 - Airway regulation, provocation and monitoring II
Session: Airway regulation, provocation and monitoring II
Session type: Thematic Poster Session
Number: 2190
Disease area: Airway diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
M. J. Cruz, S. Sanchez-Vidaurre, X. Muñoz, M. A. Ramón, L. Ruano, F. Morell (Barcelona, Spain). Reference values for pH and nitrosative stress parameters in exhaled breath condensate: impact of age. Eur Respir J 2007; 30: Suppl. 51, 2190

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Increased nitrosative stress in COPD airways: validation and measurement in exhaled breath condensate
Source: Annual Congress 2009 - COPD: from biomarker profiling to clinical assessment
Year: 2009

Normative values for exhaled breath condensate pH
Source: Eur Respir J 2005; 26: Suppl. 49, 227s
Year: 2005

Biomarkers of oxidative stress in exhaled breath condensate following ozone exposure in volunteers
Source: Eur Respir J 2001; 18: Suppl. 33, 460s
Year: 2001

Exhaled breath condensate sample collection: standards and open issues
Source: Eur Respir Monogr 2010; 49: 152-161
Year: 2010


Exhaled breath condensate pH
Source: Eur Respir Monogr 2010; 49: 173-182
Year: 2010


Exhaled breath condensate (EBC) helps the detection of oxidative stress in beta thalassemia major
Source: Eur Respir J 2006; 28: Suppl. 50, 192s
Year: 2006

Influence of inflammatory phenotype in severe refractory asthma on metabolomic profile of oxidative stress in exhaled breath condensate (EBC)
Source: Annual Congress 2013 –Assessment of airway inflammation by exhaled gases
Year: 2013


Exhaled breath condensate pH standardised for CO2 partial pressure
Source: Eur Respir J 2007; 29: 496-501
Year: 2007



Oxidative stress in children with OSAS: 8-isoprostane values comparison in urine and exhaled breath condensate (EBC)
Source: International Congress 2015 – To treat or not to treat? Sleep-disordered breathing II
Year: 2015

Dynamics of oxidative and antioxidant parameters of the exhaled air condensate in COPD.
Source: International Congress 2018 – Functional genomics and COPD: new challenges
Year: 2018

Exhaled breath condensate pH: comparing different methods
Source: Annual Congress 2009 - What is new in the regulation and monitoring of airway function?
Year: 2009

Influence of sampling time on malondialdehyde levels and pH in exhaled breath condensate
Source: Eur Respir J 2003; 22: Suppl. 45, 38s
Year: 2003

Exhaled NO and exhaled breath condensate pH in the assessment of asthma control: a real-life study
Source: Annual Congress 2009 - One size (does not) fit all: phenotyping and controlling asthma
Year: 2009



Exhaled breath condensate pH and peak flow variability in asthma
Source: Annual Congress 2008 - Inflammatory biomarkers
Year: 2008


Oxidative stress evaluation in exhaled breath condensate (EBC) vs induced sputum (IS) in the assessment of lung diseases
Source: Annual Congress 2006 - Monitoring airway inflammation – exhaled markers vs induced sputum
Year: 2006


Comparison between exhaled and sputum oxidative stress biomarkers in chronic airway inflammation
Source: Eur Respir J 2004; 24: 1011-1017
Year: 2004



Variability of the exhaled breath condensate pH with different methods of analysis
Source: Eur Respir J 2005; 26: Suppl. 49, 260s
Year: 2005

The dynamics of free radical parameters in exhaled breath condensate (EBC) in smokers during the course of physical workload
Source: Annual Congress 2011 - Smoking-related diseases and smoking cessation
Year: 2011

Quantitative analysis of 8-isoprostane and hydrogen peroxide in exhaled breath condensate
Source: Eur Respir J 2004; 23: 189-192
Year: 2004



Reproducibility of oxidative stress biomarkers in breath condensate: are they reliable?
Source: Eur Respir J 2004; 23: 183-184
Year: 2004