X5 values measured on Impulse Oscillometry (IOS) help differentiate healthy, asthmatic, COPD and ILD subjects from one another.

V. Das (PUNE, India), Y. Thorat (PUNE, India), N. Vanjare (PUNE, India), S. Rasam (PUNE, India), S. Madas (PUNE, India), R. Kodgule (PUNE, India), S. Salvi (PUNE, India), S. Pawar (PUNE, India)

Source: International Congress 2018 – Respiratory physiology and measurements
Session: Respiratory physiology and measurements
Session type: Thematic Poster
Number: 1403
Disease area: Airway diseases, Interstitial lung diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
V. Das (PUNE, India), Y. Thorat (PUNE, India), N. Vanjare (PUNE, India), S. Rasam (PUNE, India), S. Madas (PUNE, India), R. Kodgule (PUNE, India), S. Salvi (PUNE, India), S. Pawar (PUNE, India). X5 values measured on Impulse Oscillometry (IOS) help differentiate healthy, asthmatic, COPD and ILD subjects from one another.. 1403

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Post-bronchodilator response (PBDR) evaluated by plethysmographic and spirometric target parameters in patients with COPD, asthma-COPD-overlap (ACO) and asthma
Source: International Congress 2018 – Innovations in equipment and their application
Year: 2018



Small airway dysfunction by impulse oscillometry system (IOS) in asthma. Relationship with spirometry, bronchodilator response and disease control
Source: Annual Congress 2012 - Lung function tests in monitoring airway diseases
Year: 2012

Detection of bronchial asthma using impulse oscillation system (IOS) in patients with normal spirometry
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

The relationship between impulse oscillometry (IOS) and health status in patients with COPD
Source: Eur Respir J 2003; 22: Suppl. 45, 423s
Year: 2003

Assessment of repeatability of eNose (SpiroNose) measurements in healthy and asthmatic subjects
Source: International Congress 2018 – Evolving approaches to differential diagnosis
Year: 2018



Repeatability study comparing plethysmographic and spirometric lung function parameters in COPD patients, asthmatics, and healthy subjects
Source: Eur Respir J 2006; 28: Suppl. 50, 221s
Year: 2006

Impulse oscillometry (IOS) in emphysema: relationship to conventional lung function indices
Source: Eur Respir J 2003; 22: Suppl. 45, 100s
Year: 2003

Reproducibility of resistance (R) and reactance (X) responses to bronchodilator (BD) measured by the impulse oscillation system (IOS) in patients with stable COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 63s
Year: 2005

Pulmonary resistance measured by impulse oscillometry system (IOS) seems to be related to self-reported COPD and respiratory symptoms
Source: Annual Congress 2011 - Respiratory epidemiology: methods, definitions and phenotypes
Year: 2011

Comparison of airway resistance (RAW) measurements by the forced oscillation technique (FOT) and the interrupter technique (RINT) for detecting obstructive lung disease (OLD) in elderly patients
Source: Eur Respir J 2004; 24: Suppl. 48, 283s
Year: 2004

FeNO is not affected by spirometry, IOS or walking in healthy subjects or well controlled asthma patients
Source: Virtual Congress 2020 – Clinical characteristics and diagnostic tools for phenotyping asthma and COPD
Year: 2020

Impulse Ocscillometry is a reproducible assessment of airway resistance and reactance in well-controlled asthmatics and healthy controls.
Source: Virtual Congress 2020 – Clinical characteristics and diagnostic tools for phenotyping asthma and COPD
Year: 2020

Is impulse oscillometry (IOS) better than spirometry for monitoring treatment outcomes in adult cystic fibrosis (CF) pulmonary exacerbations? A pilot study
Source: International Congress 2019 – Physiology of cystic fibrosis
Year: 2019


Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects
Source: ERJ Open Res 2016: 00094-2015
Year: 2016



Clinical utility of impulse oscillometry (IOS) versus multiple breath washout (MBW) in school-age asthma
Source: Virtual Congress 2021 – Paediatric allergic asthma: novel therapeutics and monitoring approaches
Year: 2021


Overweight is related to small airway function assessed by impulse oscillometry system (IOS) in asthmatic patients with normal spirometry
Source: Annual Congress 2013 –Clinical physiology and functional imaging in health and disease
Year: 2013

Asthma control test (ACT) versus intermittent oscillation system (IOS) assessment for control of asthmatic children
Source: Annual Congress 2011 - Coping and lifestyle in childhood asthma
Year: 2011


Reproducibility of resistance (R) and reactance (X) measured with the impulse oscillation system (IOS) in patients with COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 65s
Year: 2005

Agreement of airway resistance measurements by two different techniques of body-plethysmography and impulse oscillometry in asthmatic patients
Source: Annual Congress 2011 - Lung function today and tomorrow I
Year: 2011

Impulse-oscillometry (IOS) differences in asthma and COPD patients, and healthy-subjects
Source: International Congress 2014 – Airways: reversibility and responsiveness
Year: 2014