R. Breyer-Kohansal (Wien, Austria), J. Allinson (London, United Kingdom), G. Joos (Ghent, Belgium), C. Hall (Overland Park, United States of America)
Forced oscillation technique for sensitive detection of early-stage chronic obstructive pulmonary disease L. Gao (Chengdu, China), Y. Wu (Chengdu, China), H. Wang (Chengdu, China), . Xiong (Chengdu, China), R. Qiu (Suining, China), T. Wang (Chengdu, China), . Shen (Chengdu, China), L. Chen (Chengdu, China), F. Wen (Chengdu, China)
|  |
Forced oscillation technique may identify severe asthma T. Shirai (Shizuoka, Japan), K. Hirai (Shizuoka, Japan), Y. Gon (Tokyo, Japan), S. Maruoka (Tokyo, Japan), K. Mizumura (Tokyo, Japan), M. Hikichi (Tokyo, Japan), K. Itoh (Shizuoka, Japan), S. Hashimoto (Tokyo, Japan)
|   |
Assessment of expiratory vs inspiratory resistance and reactance using FOT as a measure of air trapping A. Nasr (Lund, Sweden), L. Jarenbäck (Lund, Sweden), L. Bjermer (Lund, Sweden), E. Tufvesson (Lund, Sweden)
|  |
Impulse Oscillometry Better Differentiates the Lungs Response from Elderlies Smokers from Non-smokers T. Guimarães (São Paulo, Brazil), M. Brandão Rangel (São Paulo, Brazil), A. Araujo Rosa (São José dos Campos, Brazil), L. Sales Dias (São Paulo, Brazil), J. Mahler Quirino (São José dos Campos, Brazil), C. Murata (São José dos Campos, Brazil), G. Rocha (São José dos Campos, Brazil), A. Cardoso Moraes (São José dos Campos, Brazil), C. Frizon (São José dos Campos, Brazil), R. Vieira (São José dos Campos, Brazil)
|  |
Impulse oscillometry in adults with severe asthma L. Carreto (Amadora, Portugal), M. Silveira (Amadora, Portugal), M. Ferreira (Amadora, Portugal), C. Alves (Amadora, Portugal), H. Liberato (Amadora, Portugal), R. Melo (Amadora, Portugal), F. Rodrigues (Amadora, Portugal)
|   |
A comparative study of bedside pulmonary function tests and standard spirometry in stable COPD Patients R. Aland (jaipur, India), M. Gupta (jaipur, India)
|   |
Multiple breath washout testing after paediatric blood and marrow transplantation J. Rayment (Vancouver, Canada), R. Sandoval (Vancouver, Canada), J. Roden (Vancouver, Canada), M. Chilvers (Vancouver, Canada), K. Schultz (Vancouver, Canada)
|  |
Dynamic hyperinflation contributes to systemic and airway inflammation in patients with COPD P. Mariscal Aguilar (Madrid, Spain), R. Galera Martínez (Madrid, Spain), R. Casitas Mateo (Madrid, Spain), E. Martínez Cerón (Madrid, Spain), D. Laorden Escudero (Madrid, Spain), J. Tenes Mayen (Madrid, Spain), G. González Pozo (Madrid, Spain), F. García Río (Madrid, Spain)
|   |
The better explanation of COPD: the clinical role of FVC grouping A. Tai Joon (Seoul, Republic of Korea), S. Wan (Seoul, Republic of Korea), P. Chan Kwon (Seoul, Republic of Korea), Y. Hyoung Kyu (Seoul, Republic of Korea)
|  |
Small airways disease evaluation in healthy smokers with normal spirometry values M. Kipourou (Thessaloniki, Greece), P. Michailopoulos (Thessaloniki, Greece), X. Bikas (Thessaloniki, Greece), E. Ntinapogias (Thessaloniki, Greece), G. Spyropoulos (Thessaloniki, Greece), K. Katsoulis (Thessaloniki, Greece)
|   |
Validation study of the portable Air Next spirometer: preliminary results K. Exarchos (Ioannina, Greece), A. Sioutkou (Ioannina, Greece), C. Chronis (Ioannina, Greece), S. Peristeri (Ioannina, Greece), A. Gogali (Ioannina, Greece), A. Konstantinidis (Ioannina, Greece), K. Kostikas (Ioannina, Greece)
|   |
Evaluation of pulmonary function parameters and lung age in automobile drivers-A pilot study in a semi-urban area in South India K. Bolla (Kelambakkam, India), M. Narasimhan (Kelambakkam, India), A. Shanmuganathan (Kelambakkam, India), N. Ganga (Kelambakkam, India), R. Ragulan (Kelambakkam, India)
|  |
Using the pre-bronchodilator spirometry curvature to improve estimation of post-bronchodilator airflow obstruction S. Hangaard (Aalborg Ø, Denmark), T. Kronborg (Aalborg Ø, Denmark), M. Stausholm (Aalborg Ø, Denmark), S. Cichosz (Aalborg Ø, Denmark), O. Hejlesen (Aalborg Ø, Denmark)
|   |
How to stage airflow limitation (AL) in patients with stable COPD? I. Anane (sousse, Tunisia), F. Guezguez (sousse, Tunisia), H. Knaz (sousse, Tunisia), H. Ben Saad (sousse, Tunisia)
|   |
COPD SCREENING THROUGH COPD-6 AND PIKO-6 MICROSPIROMETERS: WHAT DEVICE IS BETTER IN REAL LIFE CLINICAL PRACTICE? M. Hernandez (Salamanca, Spain), I. De Los Santos (Salamanca, Spain), V. Hidalgo Sierra (Salamanca, Spain), S. Jodra Sánchez (Salamanca, Spain), A. Sánchez Fernández (Salamanca, Spain), R. Cordovilla Pérez (Salamanca, Spain), R. Diego Castellanos (Salamanca, Spain), M. Barrueco Ferrero (Salamanca, Spain)
|   |
Are FEV6, FVC and VC different in diagnosing obstructive ventilatory defect? C. Figueira de Sousa (Funchal, Portugal), D. Coelho (Porto, Portugal), P. Amorim (Porto, Portugal), P. Viana (Porto, Portugal), N. Martins (Porto, Portugal), M. Drummond (Porto, Portugal)
|   |
Considerable variation exists among spirometry interpretation algorithms A. D'Urzo (Toronto, Canada), K. D'Urzo (Kingston, Canada)
|   |
Aligning lung function equipment and reference values in adults. S. Verbanck (BRUSSELS, Belgium), D. Schuermans (BRUSSELS, Belgium), B. Thompson (BRUSSELS, Belgium), E. Vanderhelst (BRUSSELS, Belgium)
|  |
Reducing the variability of DLCO measurements in clinical trials A. Hagberg (Gothenburg, Sweden), J. Betts (Gothenburg, Sweden), C. Kristensson (Gothenburg, Sweden), J. Mo (Gothenburg, Sweden), S. Asimus (Gothenburg, Sweden), M. Sadiq (Gothenburg, Sweden), T. Koernicke (Berlin, Germany), R. Fuhr (Berlin, Germany), W. Brailsford (Gothenburg, Sweden), C. Keen (Gothenburg, Sweden), J. Mäenpää (Gothenburg, Sweden)
|   |