D. Schuermans (Brussels, Belgium), M. Swanney (Christchurch, New Zealand)
LATE-BREAKING ABSTRACT: All-age multi-ethnic reference values for spirometry: The global lung function initiative (GLI) J. Stocks, S. Stanojevic, T. Cole, X. Baur, G. Hall, B. Culver, P. Quanjer (London, United Kingdom; Toronto, Canada; Hamburg, Germany; Perth, Australia; Seattle, United States Of America; Rotterdam, Netherlands)
| |
A comparative study of FVC, FEV1, and TLC in non-smoking Saudi students at Eastern Province, Saudi Arabia with Caucasian reference values N. AL-Khathlan, S. Enright, M. A. El-Noueam (Cardiff, United Kingdom; Dammam, Saudi Arabia)
| |
Reference values for spirometry in healthy subjects 17 to 25 years I. Gonçalves, B. Tavares, S. Gomes, T. Jacinto (Vila Nova de Gaia, Maia, Porto, Portugal)
| |
Spirometry measurements in the morbid obesity K. Abu Shams, M. Hernandez, A. Iridoy, S. Clemos (Pamplona, Spain)
| |
Comparison of different predicted and lower limit of normal (LLN) values in ventilation disorders detection M. Kameneva, A. Tishkov, A. Bykhova, V. Trofimov (Saint Petersburg, Russian Federation)
| |
The effect of body composition on pulmonary function J.E. Park, J.H. Chung, K.C. Shin, K.H. Lee (Daegu, Republic Of Korea)
| |
Reference values for exhaled breath temperature in healthy subjects aged 17 to 25 years old B. Tavares, I. Gonçalves, S. Gomes, T. Jacinto (Maia, Porto, Portugal)
| |
Forced oscillation technique (FOT) reference values: Does one size fit all? C. Shackleton, A. Barraza-Villarreal, I. Romieu, C. Calogero, G. Hall, P. Sly (Brisbane, Perth, Australia; Morelos, Mexico; Florence, Italy; Lyon, France)
| |
Impact of a pulmonary laboratory quality control oversight on continual improvement C. Mottram, S. Blonshine, K. Kijek, J. Road (Vancouver, Canada)
| |
Validation of spirometer calibration syringes F. Madsen (Helsingør, Denmark)
| |
The comparison study on the effects of high versus low flux membrane on pulmonary function tests in hemodialysis patients A. Momeni, H. Rouhi Boroujeni, G. Kiani, M. Amiri (Shahrekord, Islamic Republic Of Iran)
| |
Pulmonary volumetric analyses based on three-dimensional computed tomography (3D-CT), compared with pulmonary function test H. Wada, S. Hiraoka, K. Morita, M. Koyanagi, K. Yokoyama, Y. Fukuchi, T. Nitatori, H. Goto (Tokyo, Japan)
| |
A new ultrasonographic device for within-breath measurements of diaphragm thickness during breathing D. Bovio, A. Biancardi, G. Gobitti, M. Laviola, B. Uva, R. Priori, A. Aliverti (Milan, Italy)
| |
Estimation of chest-wall mechanics by laser self mixing interferometer I. Milesi, E. Zannin, P. Kostic, M. Norgia, C. Veneroni, A. Pedotti, P. Frykholm, R. Dellacà (Milan, Italy; Uppsala, Sweden)
| |
Specificity and sensitivity of the methacholine challenge test for the diagnosis of asthma in athletes T. Molostova, A. Cherniak, T. Pashkova, M. Mustaphina, S. Chikina, Z. Aisanov (Moscow, Russian Federation)
| |
Bronchial hyper-reactivity diagnosed by methacoline challenge and the pre-test clinical probability D. Ionita, I. Stoicescu, D. Dospinoiu, C. Nita, F. Cojocaru, M. Burecu, A. Croitoru, C. Stroescu, I. Strambu (Bucharest, Romania)
| |